Beyes XR2011 DURAY V2, DC Intraoral X-Ray

Beyes XR2011 DURAY V2, DC Intraoral X-Ray

The Beyes XR2011 is the manufacturer part number for the DURAY V2 DC Intraoral X-Ray Unit. It is an advanced, lightweight dental X-ray system designed to deliver high-resolution diagnostic imaging while minimizing patient radiation exposure. 

Excellent image quality

Thanks to the selectable tube voltage of 60 and 70 kV you can adjust the image contrast and gray shades needed for detailed diagnosis. Finest focal spot of 0.4, advanced DC technology and a wide range of preset exposure settings ensure excellent image quality with every exposure.

 


Thumb precise settings for every exposure

 

Precise settings for every exposure

You can be sure to get the best image quality with every exposure. Set the right exposure settings quickly and intuitively in just three steps: select from 2 patient sizes, 9 preset anatomical programs and 3 detector types. Voltage can be changed from 60 to 70 kV to adjust the image contrast and grayscale.

 


Thumb remote solution

 

Remote solution

The wall mount and timer can be installed separately allowing to control the exposure from outside the X-ray room. This solution ensures radiation safety as well as easy installation and integration into your dental practice.

 


Thumb automatic dap display

 

Automatic DAP display

Duray V2 provides appropriate exposure settings that ensure high quality images. The built-in DAP (Dose Area Product) allows dose monitoring, thus supporting safety procedures and patient radiation protection. The dose can be shown with every exposure on the XDC control panel display.

 


Thumb rectangular beam limiting device

 

Rectangular beam limiting device

Reduce the patient dose by using the optional rectangular beam limiting device available in film size 0 and 2.

 


Thumb 30 cm collimator

 

30 cm collimator

Thanks to the optional 30 cm collimator image magnification can be reduced increasing thereby the sharpness of your radiographic images.

 

Please note that for international transactions, customers will be responsible for import taxes, clearance, and duty taxes.

Key Specification:

Generator Direct Current (DC)
Focal Spot 0.4 (IEC 336/1997)
Tube voltage 60 kV / 70 kV (selectable)
Tube current 7 mA
Line voltage 100 / 230 V, 50/60 Hz
Focus – Skin Distance Standard 20 cm (optional 30 cm)
Exposure time 0.01 – 3.2 s
Patient Size Programs Adult, Child
Number of Preset Anatomical Programs 9
Preset Detector Programs Film, Phosphor Plate, Sensor
Useful reach – with SSD 20 cm 143 cm – with short extension arm (30 cm) 173 cm – with medium extension arm (60 cm) 193 cm – with long extension arm (80 cm) 213 cm – with extra long extension arm (100 cm)
Useful reach – with SSD 30 cm 133 cm – with short extension arm (30 cm) 163 cm – with medium extension arm (60 cm) 183 cm – with long extension arm (80 cm) 203 cm – with extra long extension arm (100 cm)