RADWAG DUAL PIPETTE CALIBRATION WORKSTATION WITH MYA.21.4Y.P MICRO BALANCE, XA 52.4Y.M.A.I.P SEMI MICRO BALANCE, ANTIVIBRATION TABLE, AND PC WITH PIPETTE CALIBRATION SOFTWARE

RADWAG DUAL PIPETTE CALIBRATION WORKSTATION WITH MYA.21.4Y.P MICRO BALANCE, XA 52.4Y.M.A.I.P SEMI MICRO BALANCE, ANTIVIBRATION TABLE, AND PC WITH PIPETTE CALIBRATION SOFTWARE

 

OVERVIEW

Overview

In order to ensure measurement traceability, meet all the requirements resulting from supervision over measuring equipment and to facilitate  the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration.


Application:
Calibration of automatic pipettes:

  • with fixed volume
  • with adjustable volume.

Unit contents:

  • table for calibration
  • anti-vibration table
  • probe for temperature, humidity and pressure measurement
  • probe for water temperature measurement
  • sink for used water
  • armrests
  • LCD monitor
  • PC with pre-installed software PIPETTES RADWAG
  • power supply
  • keyboard and mouse
  • container for used water


Adapters for pipettes calibration

Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table presents the minimum reguirements in accordance with ISO 8655 standard. It also enables to select suitable adapter for pipette calibration and respective balance version.

Please note that for international transactions, customers will be responsible for import taxes, clearance, and duty taxes.

Selected volume1 of apparatus under test
V
Resolution
mg
Repeatability and linearity
mg
Recommended balance
1 µl ≤ V ≤ 10 µl 0.001 0.002 MYA 21.4Y PLUS
MYA 21.4Y
XA 6/21.4Y.M.A PLUS
XA 6/21.4Y.M.A
XA 6/21.4Y.M
 
10 µl < V ≤ 100 µl 0.01 0.02 XA 82/220.4Y.A PLUS
XA 82/220.4Y.A
XA 82/220.4Y
XA 120/250.4Y.A PLUS
XA 120/250.4Y.A
XA 120/250.4Y
100 µl < V ≤ 1000 µl 0.1 0.2
1 ml < V ≤ 10 ml 0.1 0.2
Adapter for pipette calibration MY 11 XA 11 XA 17 XA 100 XA 17 XA 100
Maximum vessel capacity 11 ml 11 ml 17 ml 100 ml 17 ml 100 ml
Weighing vessel mass ~10 g ~10 g ~11 g ~65 g ~11 g ~65 g


1 For practical purposes, the nominal volume may be used to choose the balance. [Reference: ISO8655-6:2002, pg. 2]
If the standard uncertainty of measurement of the balance is known (e.g. from the balance calibration certificate), it may be used instead of the repeatability and linearity. The standard uncertainty of measurement shall not be more than two to three times the resolution. [Reference: ISO8655-6:2002, pg. 2]


Manufacturer: Radwag
Country of Origin: Poland
Weighing Surface: Non-scratch Granite
Construction: Painted steel
Weighing Platform Dimensions: 410 mm (length) x 270 mm (width)
Overall Dimensions:1120 mm (length) x 750 mm (width) x 1070 mm (height)
Balance Included:MYA.21.4Y.P
Capacity of MYA.21.4Y.P Micro Balance:21 g
Readability of MYA.21.4Y.P Micro Balance:1 µg / 0.000001 gram
Repeatability of MYA.21.4Y.P Micro Balance:1.2 µg - 3 µg
Linearity of MYA.21.4Y.P Micro Balance:± 7 µg
Capacity of XA 52.4Y.M.A.I.P Semi Micro Balance:52 g
Readability of XA 52.4Y.M.A.I.P Semi Micro Balance:0.01 mg
Repeatability of XA 52.4Y.M.A.I.P Semi Micro Balance:0.01 mg
Linearity of XA 52.4Y.M.A.I.P Semi Micro Balance:± 0.03 mg
Calibration: Automatic internal
Stabilization Time:10 seconds or less
Minimum Weight: 0.1 mg
Construction: 2 x USB, 2 x RS232, Ethernet, 4 input/4 output
Display Type: 5.7" Color Touchscreen
Operating Temperature: 50° to 104° F / 10° to 40° C